High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building.

Is your building permanently used E.G. Hotels, then you need to test the lights so that the end of the test corresponds to the start of day. In this way the emergency lights will have a good time to recharge during daylight hours. Natural daylight will help if the emergency lights don’t last 3 hours. Should I test ALL emergency lights at once? Be very careful when touching anything inside the electrical consumer box, there is a danger of electrocution if something is wrong. If in doubt seek a qualified electrician ** What time of day should I test the emergency lights Annual emergency lighting tests need to be carried out by a professional technician. This will involve testing your system for the full duration – usually three hours – and is commonly paired with testing your fire alarm.Emergency lighting should be tested monthly in between servicing visits. Here is an example of what an emergency light looks like.

Emergency lighting testing requirements stipulate that emergency lighting must be maintained and regularly tested in the same way as other emergency equipment. Each light should be identified and have a location identity for recordkeeping. A record log can then be kept of the system test, defects, any damage to the system, and remedial action relating to each light. Emergency lighting is essential for safety in commercial buildings. Whether you manage an office building, a retail unit or a leisure facility, you should have working emergency lighting to help meet the requirements set out in BS 5266:2016, which stipulates the need for buildings to have adequate illumination when mains power fails. Here at the Fire Protection Association, we offer a 5-day Fire Detection, Alarms, and Emergency Lighting training course that provides a comprehensive understanding of systems, legislation, and standards including BS 5266-1 and BS 5839, as well as practical guidance for carrying out installation, commissioning, and maintenance of systems. Find out more here. Areas in which there is moving machinery or vehicles, flammable materials or control rooms associated with potentially dangerous processes have, as ‘high risk task areas’, slightly different requirements in relation to emergency lighting – particularly in relation to the illuminance levels to be maintained and duration of operation. High risk task area lighting is provided predominantly to ensure that processes can be safely terminated, and occupants make their evacuation from the area without undue risk from the process.Failure of the normal lighting does not necessarily mean that the hazard no longer exists. A hazard may continue long after failure of the normal lighting supply. In such circumstances, high risk task lighting will be required and designed in such a way to ensure illumination is maintained as long as the local hazard continues to exist.

The team here at Fire Trade Supplies have assembled a collection of Fish Key Emergency Lighting including F9099 grid keys (PK6), Multi-EL (3 pairs of assorted EL keys), EL key - crabtree style (PK6) as well as many more combinations which can all be found in our store. With so many pieces of legislation and regulations covering emergency lighting, we thought it would be a good idea to cover how to test your emergency lighting. There are many different types of emergency lights and different types of emergency lighting test facilities however most of these different pieces of equipment are generally tested and inspected in a similar way.UK fire safety legislation states that emergency lighting is required in buildings to provide light if normal lighting fails during a fire. We can provide emergency lighting testing and servicing to ensure you are fire safety compliant. We can test your emergency lighting system at a time that suits you. The results of all testing and any necessary corrective action can be recorded in your fire safety logbook. This record is then available for inspection if required. The frequency in which you should get your emergency lighting tested can vary depending on system type (i.e. maintained emergency lighting or non-maintained), but as a general guide, you should aim to get your emergency lighting system tested monthly, in addition to an annual ‘full duration’ test as described in BS 5266-1.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment